Skip to main content

Request an Inspection

Basic Text

Requests for Inspection must be made before 12:00 Noon the day prior to the date of Inspection

Requirements

  • Permit number or work order number
  • Job title
  • Valid USA Dig number
  • Address or location of project will be required information to schedule an inspector.

The Bureau of Contract Administration Dispatch Group is responsible for the daily scheduling of inspections by Contractors and Bureau Inspectors in the Metropolitan, Valley, West Los Angeles, and Harbor areas of the City.

This group is responsible for the scheduling of inspections of Class A and B permits, Cash Contracts, Sewer Connection permits, General Deposit permits, Special Deposit permits, Utility permits Excavation permits, and batch plant inspection throughout the City.

Dispatch also provides inspection schedules for lateral support permits, which are permits to shore up the public right of way when developers are excavating large deep areas for private construction of buildings or garages.

Most of these permits are taken out by the various private developers, water, power, telephone and cable companies that service the City.

Dispatch System Schedule

Please use the dropdown options below and click on "Search" to filter by District, Job Type, Work Order/Permit, or Inspector.

  • The information on this table is accurate as of 12:00 noon the day prior to the date of inspection. On Fridays, this table is updated to show the weekend and Monday schedule and is accurate as of 12:00 noon on that Friday prior to the weekend/Monday.
  • Click on the District dropdown to filter by Metro East, Metro West, or Valley districts.
  • Click on the Job Type dropdown to filter by Materials Control (MC) or Shop Fabrication (SF), or Permit Type.
  • Click on the Inspection Date to filter by Saturday, Sunday, or Monday inspections if needed.
  • Click on the Inspector dropdown to filter by Inspector assigned.
  • Enter Work Order/Permit in the specific input box to filter by Work Order/Permit.
  • Click the "Reset" button to clear filters.

For inspectors, please go to the Dispatch Application for more up-to-date information if needed.

For customers, please go to the Appointment Request page for any requests or information..

District Inspection District Job Type WO/Permit Address Job Title T.B. Map Onsite Contact Time Plant/Work Quantity Unit Inspector Sort descending Material Type Line No.
Metro West 3a U 2025850810 11250 LA GRANGE AVE., Los Angeles CA 90025 38 UNIT APARTMENT BLDG 632 6B DARREN 951-207-4211 ALCRETE INC 7/10/26, 9:00 AM CONTINUING WORK IN THE P.R.O.W., EXCAVATE / TRENCH FOR POWER CONDUIT INSTALL Maximiliano Vasquez 807091MW
Metro West 3a U 2025850810 11250 LA grange ave Los Angeles ca 91007 38 UNIT APARTMENT BLDG 632 6B Kyle 951-496-1845 Alcrete 7/10/26, 10:00 AM Install conduit Maximiliano Vasquez 807086MW
Metro West 5 U 2026850939 700 Sarbonne Rd Chalon Los Angeles CA 90077 CPD Not #2043973381 592 7A Víctor 562-382-5591 Henkels & McCoy 7/10/26, 12:30 PM Install anode for SoCal gas Maximiliano Vasquez 807024MW
Metro West 5 U 2024851263 10825 W. Pico Bl, Los Angeles CA 90064 34.5KV CONDUIT CUSTOMER REQUIREMENT 632 6C Chad Tamm 213-791-6778 LADWP 7/10/26, 10:00 AM Traffic control, conduit installation, concrete encasement and slurry backfill Maximiliano Vasquez 806475MW
Metro East 2c CCI Swc08399 1433 Valencia st,los angeles Ca 90015 Demetrio Zamarron 323-690-9156 Vidmar 7/10/26, 9:00 AM Manhole remodel. Michael Gonzales 807000ME
Metro West 3b CCI SZC14473 140 Hurricane St Marina Del Rey CA 90292 Juan Reyes 626-655-9905 MNR Construction Inc. 7/10/26, 7:00 AM Valve Replacement Michael Guerrero 808117MW
Metro West 3b CCI szc14469 138 Hurricane St, Marina Del Rey, CA 90292 Evan Casaus 909-660-9543 Mike Prlich and Sons, Inc 7/10/26, 7:00 AM AST slab work Michael Guerrero 806829MW
Metro West 3a B BR403097 1587 N. Bundy Dr., Los Angeles CA 90049 BUNDY DR. (1587) N/O CHALON RD. (SEWER IMPROVEMENTS) 591 6F DOMINIKA BUDZ 949-306-4265 DOMA Development 7/10/26, 9:00 AM sewer line connection Michael Rodriguez 806417MW
Metro West 3b B BR403227 Sepulveda blvd and 98th 90045 DESIGN UNIT 2A ATMP Segments A, C, D, & F Jimmy Prickett 951-203-5340 SFJV 7/10/26, 7:30 AM Grading for falsework Michael Smith (LAMP) 808353MW
Metro West 3b U 2026850118 6300 W 96th st., Los Angeles, CA, 90045 ATMP - AC02 - DWP-W West Sepulveda 702 5G Genaro Xicotencatl 805-754-9436 Blois Construction, LLC 7/10/26, 12:00 AM Pavement trench area of the 3" copper water line and 12" new water line Michael Smith (LAMP) 808196MW